Principle
The calculation and measurement are based on the principle of "transverse vibration of string".The tester will pick up the vibration of the belt and record it as a frequency.Enter the mass, width, and span
in the following formula.frequency
The relationship between and tension can be calculated in the following formula: T=4xMxWxS2 xF2 x10-9
Measuring range | 10Hz-680Hz |
Belt free strand length | Max 999.9 mm |
Belt width | Max 999.9 mm/R |
Belt mass | Max 999.9 g/m |
Precision |
±1HZ<100HZ AND ±1%>100HZ |
Digital sampling accuracy | < 1% |
Display accuracy | ±1Hz |
Overall accuracy | < 5% |
Operating temperature |
+10° C~ +50° C |
Transport temperature | -5 ° C~-70° C |
Display |
LCD |
Measurement unit |
Hz/N |
Power supply |
4×1.5V AAA |
Housing | Plastic(ABS) |
Dimensions |
140mmx7mm2x34mm |
Package size | 248mmx206mmx52mm |
Standard Accessories | Main Unit (one) |
Operating Instructions (one copy) | |
Portable suitcase(one) |