Standard Applied |
IEC61252, ANSI S1.25 - 1992 for dose meter and sound exposure meters. IEC 61672-1-2013 Class 2 |
Microphone |
1/2-inch electret condenser microphone with 31-inch integral cable |
Display |
Liquid Crystal Display |
Measurement Ranges (Linearity and Indicator ranges at 4KHz) |
60 - 130 : 60 - 130dB (A and C) |
70 - 140 : 70 - 140dB (A and C) |
Peak Ranges (C-weighted or Linear Peak over the top 40dB of each measurement range) |
60 - 130 : 93 - 133dB Peak |
70 - 140 : 103 - 143dB Peak |
Frequency Weightings |
RMS Detector: A or C |
Peak Detector: C or Z (Linear) |
Time Weightings |
Fast and Slow (RMS detector) |
Exchange Rate |
3, 4, 5 or 6dB |
Stabilization Time |
10 seconds from power on |
Threshold and Criterion Levels (From the setup, predefined in the built - in setup according to applicable standards) |
User-defined setups in the following ranges : |
Threshold Level : 70 - 90dB in 1dB steps |
Criterion Level : 80, 84, 85 or 90dB |
Criterion Level : 80, 84, 85 or 90dB |
At 0.1dB above the top of the selected measurement range |
At 0.1dB above the top of the selected measurement range |
Under-Range Indications |
High Level Detector |
115dB |
Keypad Lock |
Lock and unlock by pressing key combinations: Up and right arrows to lock; left and down arrows to unlock |
Clock |
Real-time clock with calendar |
Memory |
Results from 50 measurements can be stored for later viewing and download |
Measurement Control |
Measurement Duration : May be set to 5, 10, 15, or 30 minutes or 1, 2, 4, 8, 10, 12, or 24 hours |
Timers |
Up to 16 timers(automatic start and stop)can be set(maximum up to one month ahead of measurement time) |
Timer Controlled Started / Stop |
Set up from the PC software or meter keypad |
Logging |
All measurement parameters values can be logged |
Logging Period (LP) |
1s, 2s, 5s, 10s, 15s, 20s, 30s, 1min, 2min, 5min, 10min, 15min, 20min, 30min or 60min |
Logging Capacity |
120000 values can be stored at any one time |
Setup |
Eight built-in (predefined) default setups are included. Nine additional user-defined setups can be stored |
Output |
USB interface |
Power Supply |
4x1.5V AAA Size (UM-4)Battery |
Battery Indicator |
Symbol indication battery voltage level in 4 steps. Indicator flashes when voltage is insufficient for operation |
Operating Temperature & Humidity |
0 - 50ºC (32 to 122ºF) ,10 - 90%RH |
Storage Temperature & Humidity |
-10 - 60ºC(14 to 140ºF) ,10 - 75%RH |
Size |
140x72x34mm |
Weight |
Approx. 350g (including batteries) |